Prophet VS Rack unit

Shalebridge 1.45 OS (3rd party improvements on official OS releases)

Synthtaste Power Supply (replaced original power supply with new Synthtaste unit).

New OLED display

Prophet VS Model 240 RAM cartridge

Prophet VS 241-02 ROM Cartridge

Original Manual

All maintenance/upgrade work performed by Warren McAllister former owner of Phase Engineering Sydney

VS ships with original OS 1.2 chips that were removed when the Shalebridge 1.45 OS was installed and original LCD display.

Quick summary of Shalebridge OS new features and bug fixes:

NV PROGRAM NUMBER: Program Number is now remembered after power off

DATA INC/DEC: Data increment/decrement function has been added for fine adjustment

LFO SYNC: By default the VS has free running LFOs. If you change the 8th digit of the patch name to an 'S' (e.g. "Zenny 1S") then both LFOs are synced to the keys. If the 8th digit is an 'X' ("Zenny 1X") only LFO 1 is synced. LFO 2 will free-run!

ARP SYNC: Arpeggios are synced with the playing of the first note. Clock is reset when the first note is played.

LFO Sync & ARP Sync menu options: Adds "LFO Select" and "ARP Option" menu items, both are global features and saved in memory.

MASTER TUNE: Under the master tune screen a field has been added which provides a +\- 12 semitone transposition!!

LOCAL ON/OFF: Under the MIDI options switch a screen has been added to provide local keyboard enable and disable.

NRPN MSB/LSB IN & OUT: The original software had the byte order flipped LSB->MSB so many controllers (BCR2000, BeatStep Pro, etc) would not function correctly. HUGE IMPROVEMENT!

MIDI BUG FIX: In the original code, both ARP Rate and Split Point were disabled in the MIDI routine. The ARP Rate MIDI bug is fixed so now its NRPN controllable. If the ARP is off and you send the Rate NRPN then the ARP will turn on.

No comments:

Post a Comment

To reduce spam, comments for posts older than one week are not displayed until approved, usually same day. Do not insult people. For items for sale, do not ask if it is still available. Check the auction link and search for the item. Auctions are from various sellers and expire over time. Posts remain for the pics and historical purposes. This site is meant to be a daily snapshot of some of what was out there in the world of synths.

PREVIOUS PAGE NEXT PAGE HOME


Patch n Tweak
Switched On Make Synthesizer Evolution Vintage Synthesizers Creating Sound Fundlementals of Synthesizer Programming Kraftwerk

© Matrixsynth - All posts are presented here for informative, historical and educative purposes as applicable within fair use.
MATRIXSYNTH is supported by affiliate links that use cookies to track clickthroughs and sales. See the privacy policy for details.
MATRIXSYNTH - EVERYTHING SYNTH